Aller au contenu

Fiche vulnérabilité

CVE-2021-27276 : faille élevée netgear prosafe network management… (CVSS 7.1)

Description

This vulnerability allows remote attackers to delete arbitrary files on affected installations of NETGEAR ProSAFE Network Management System 1.6.0.26. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the MibController class. When parsing the realName parameter, the process does not properly validate a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-12122.

En bref

Sévérité
Élevée (CVSS 7.1)
Vecteur CVSS
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H
Exploitation active
Non signalée par la CISA
Publication
29 mars 2021
Dernière mise à jour
17 juin 2026

Produits concernés

  • netgear prosafe network management system

Références

Rechercher une autre vulnérabilité dans la base CVE